What was found
EICAS FLAP FAIL ON FINAL APPROACH. FLAP POS SHOWING 1. CHECKED ELEC CONNECTORS ON FECU, VEL SENSORS, AND FPRU. PERFORMED GVI ON FLAP MECH LINE. OPERATIONS CHECK SATISFACTORY, NO DEFECTS FOUND.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EICAS FLAP FAIL ON FINAL APPROACH. FLAP POS SHOWING 1. CHECKED ELEC CONNECTORS ON FECU, VEL SENSORS, AND FPRU. PERFORMED GVI ON FLAP MECH LINE. OPERATIONS CHECK SATISFACTORY, NO DEFECTS FOUND.