What was found
SERVICE DOOR LOWER STRINGER 16R BETWEEN FRAMES 20 AND 22 RH SHOWS CORROSION EVIDENCE. REMOVED DAMAGE CHANNEL. LOCATED, DRILLED AND INSTALLED NEW CHANNEL AT SERVICES DOOR LOWER CUT OUT BETWEEN FR 20 - FR 22. APPLIED ALODINE, PRIMER AND TOP COAT HOLES AND RIVET HEAD.