What was found
PACK 1 VALVE CLOSED MESSAGE 4 TIMES DURING CLIMB. INSPECTED AND FOUND PACK #1 HEAT EXCHANGER HOSE TORN. R&R PACK #1 EAT EXCHANGER HOSE, PACK OPS CHECK GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PACK 1 VALVE CLOSED MESSAGE 4 TIMES DURING CLIMB. INSPECTED AND FOUND PACK #1 HEAT EXCHANGER HOSE TORN. R&R PACK #1 EAT EXCHANGER HOSE, PACK OPS CHECK GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME