What was found
BRACKET BEHIND WINDSHIELD CENTER POST AT THE INNER UPPER WEB STRUCTURE HAS SCRATCH MARKS AND CRANKED AT NUT-PLATE HOLE (MARKED) INSTALLED EWIS PROTECTION AREA IAW EMB145 SWPM 20-21-00, CUT OUT DAMAGE, FABRICATED 2EA DOUBLER FROM 2024T3 .080", APPLIED ALODINE, PRIMER, AND TOP COAT IAW EMB145 CPM 51-21-04, 51-21-05, 51-21-06. INSTALLED 2EA DOUBLER REPAIR AT COCKPIT WINDSHIELD CENTER POST IAW ETD 2021-145-025064 REV A. REMOVED EWIS PROTECTION IAW EMB145 SWPM 20-21-00