As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
2X CRACK FOUND ON PYLON YOKES UPPER FLANGE AT 2X HOLE LOCATION. INSTALLED LH AND RH BUSHINGS AND PERFORMED COLD WORK BUSHING HOLES THEN REAMED FULL SIZE AND INSTALLED NEW JO-BOLTS AND WASHERS WET INSTALLED AND RESTORED FINISH ALL FASTENERS.