What was found
DENTS AT FR16 & FR15 BETWEEN STRINGER 16R & 17R NEAR SKIN SPLICE HAS OIL CANNING. PERFORMED HFEC ON THE CUT STRINGER. NO CRACKS FOUND. ENLARGE CUT-OUT. FABRICATED DOUBLER/FILLER, MATCH DRILLED FASTENER LOCATIONS, COUNTER SUNK FOR BRF2AD5 RIVETS, BEGAN INSTALLATION OF REPAIR, USING BRILES RIVETS, APPLIED SEALANT TO PATCH AND RIVETED PATCH INTO PLACE , PERFORMED RII INSPECTION ON THE FABRICATED DOUBLER, WITNNESSED THE INSTALLATION OF THE REPAIR, PERFORMED INSPECTION BUY BACK FOR THE PATCH INSTALLATION.. PRE PARED & PAINTED EXTERIOR REPAIR AREA. PERFORMED RVSM SKIN WAVINESS INSPECTION VERIFIED RVSM SKIN WAVINESS INSPECTION. SKIN WAVINESS ANALYSIS PASS, PERFORMED LEAK CHECK OF REPAIR AREA. LEAK CHECK SAT.