What was found
RH OMEGA BEAM AT FR 22 FLOOR DOUBLER FOUND CORRODED. AT RH OMEGA BEAM AT FR 22, DOUBLER FOUND CORRODED OUT OF LIMITS. DOUBLER REMOVED, DRILLED NEW HOLES FOR NEW DOUBLER. AT RH OMEGA BEAM AT FR22, NEW DOUBLER INSTALLED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RH OMEGA BEAM AT FR 22 FLOOR DOUBLER FOUND CORRODED. AT RH OMEGA BEAM AT FR 22, DOUBLER FOUND CORRODED OUT OF LIMITS. DOUBLER REMOVED, DRILLED NEW HOLES FOR NEW DOUBLER. AT RH OMEGA BEAM AT FR22, NEW DOUBLER INSTALLED.