What was found
CF1 CENTER OMEGA BEAM BTW FR 18-20 FOUND CORRODED. AT CF1 CENTER OMEGA BEAM BTW FR 18-20 WIRES UNSECURED FOR ACCESS, CORROSION BLENDED OUT OF LIMIT. CF1 CENTER OMEGA BEAM BTW FR 19-24 REMOVED FOR REPLACEMENT. CF1 NEW CENTER OMEGA BEAM BTW FR 19-24 DRILLED. CF1 CENTER OMEGA BEAM BTW FR 19-24 REPLACED. AT CF1 CENTER OMEGA BEAM BTW FR 18-20 WIRE REINSTALLED.