What was found
CENTER GUSSET BTW FR 59-61 FOUND CORRODED. CENTER GUSSET BTW FR 59-61 BLENDED AND FOUND OUT OF LIMIT. CENTER GUSSET BTW FR 59-61 REMOVED AND REPLACED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CENTER GUSSET BTW FR 59-61 FOUND CORRODED. CENTER GUSSET BTW FR 59-61 BLENDED AND FOUND OUT OF LIMIT. CENTER GUSSET BTW FR 59-61 REMOVED AND REPLACED.