What was found
FORWARD CARGO DOOR CUTOUT HAS CORROSION AT FASTENERS AROUND LIGHTENING HOLES ALONG AFT EDGE BS 430, LONGERONS 26 - 28R. REPAIRED THE WEB IAW SRM 51-70-4 FIG 1 AND 51-60-0 FIGURE 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD CARGO DOOR CUTOUT HAS CORROSION AT FASTENERS AROUND LIGHTENING HOLES ALONG AFT EDGE BS 430, LONGERONS 26 - 28R. REPAIRED THE WEB IAW SRM 51-70-4 FIG 1 AND 51-60-0 FIGURE 1.