ON CLIMB OUT #1 ENGINE STRUT OVERHEAT LIGHT ILLUMINATED. FOUND LOOSE PNEUMATIC DUCK CLAMP IN #1 PYLON LEAKING, RE SECURED DUCT CLAMP IAW B727 AMM 36-00-01, LEAK CHECK GOOD NO DEFECTS NOTED AT THIS TIME.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON CLIMB OUT #1 ENGINE STRUT OVERHEAT LIGHT ILLUMINATED. FOUND LOOSE PNEUMATIC DUCK CLAMP IN #1 PYLON LEAKING, RE SECURED DUCT CLAMP IAW B727 AMM 36-00-01, LEAK CHECK GOOD NO DEFECTS NOTED AT THIS TIME.