What was found
AFTER V1 TILL CLIMB, THRUST INTERMITTENT FALSE FIRE WARNING ON GLARE SHIELD. FIRE WARNING LT AND BELL. REMOVED, INSPECTED AND RE-INSTALLED FIRE WARNING DETECTION CARDS IAW B747 MM 26-10-00, P.401, 402, 403, AND 404. NO DEFECTS NOTED. OPS CHECKED FIRE DETECTION SYSTEM IAW B747 MM 26-11-00, 26-14-00, 26-15-00, 26-17-00 AND 26-16-00. NO DEFECTS NOTED. ALL DETECTION SYSTEMS OPERATE AND TEST NORMALLY.