What was found
FOUND CRACK INDICTION WITH HFEC OPEN HOLE INSPECTION ON R/H UPPER HOLE OF STRINGER 11 STATION 2598.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CRACK INDICTION WITH HFEC OPEN HOLE INSPECTION ON R/H UPPER HOLE OF STRINGER 11 STATION 2598.