What was found
WHILE ACCOMPLISHING SB 747-53A2427 FIG 2 AT STA 2598 RH SIDE FOUND 2 EA FASTENER HOLE WITH CRACK INDICATION COMMON TO FWD INNER CHORD AND UPPER SPLICE FITTING (3RD AND 4TH HOLES FROM TOP TO BOTTOM)