What was found
DOOR ENTRY L5 ADVISORY IN FLIGHT ACCOMPLISHED QRH PROCEDURE. PRESSURIZATION NORMAL. TRANSFERRED TO DMI 100338109 IAW KA MEL 52-73-01. CAT C. DUE 8.6.26. M PROCEDURES CW. PLACARDS INSTALLED. REF TO DMI #100338109, L5 DOOR INDICATION INOP. CORRECTIVE ACTION: FOUND ELECTRICAL CONNECTORS FOR DOOR IND. SWITCH LOOSE, RESECURED ELEC. CONNECTORS IAW B747 AMM 52-71-01, OPS CHECK NORMAL IAW AMM 52-71-00. THIS CLEARS DMI #100338109, PLACARDS REMOVED.