What was found
FOUND 2EA CRACK INDICATIONS IN FASTENER HOLES AS MARKED AT STA 1160 TENSION TIE TO FRAME ATTACHMENT LOCATIONS L/H
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND 2EA CRACK INDICATIONS IN FASTENER HOLES AS MARKED AT STA 1160 TENSION TIE TO FRAME ATTACHMENT LOCATIONS L/H