As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NR 2 GEN CAUTION LIGHT CAME ON IN FLIGHT FOLLOWED BY EMERGENCY LIGHTS WHICH CAME ON, THEN WENT OUT RECYCLED NR 2 AC GENERATOR SWITCH, BUT CAUTION LIGHT CAME ON AGAIN. AIRCRAFT FERRIED BACK TO HNL. REMOVED AND REPLACED NR 2 AC GENERATOR IAW DHC8MM 24-21-00 PAGE 201-202. OPS CHECK GOOD IAW DHC8MM 24-21-00 PAGE 205 SECTION B LEAK CHECK GOOD IAW PWC MM 72-01-00 PAGE 501. (M)