What was found
A 2 INCH CRACK 2 PLACES AT FS 755 BL 30 LT 1 INCH X 6 INCH ABOVE WHEEL WELL (INTERCOSTAL). DYE PENETRANT AREA FOUND DEEP TOOL MARKS, BLENDED WITHIN LIMITS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
A 2 INCH CRACK 2 PLACES AT FS 755 BL 30 LT 1 INCH X 6 INCH ABOVE WHEEL WELL (INTERCOSTAL). DYE PENETRANT AREA FOUND DEEP TOOL MARKS, BLENDED WITHIN LIMITS.