What was found
DURING SCHEDULED C2 INSPECTION PER JOB CARD HSP53161, FOUND LT RAMP CHINE PLATE LOWER SURFACE CORRODED RAMP STATION 0 TO 2. REPLACED CHINE PLATE PER SRM SMP 583-52-60 AND 51-30.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C2 INSPECTION PER JOB CARD HSP53161, FOUND LT RAMP CHINE PLATE LOWER SURFACE CORRODED RAMP STATION 0 TO 2. REPLACED CHINE PLATE PER SRM SMP 583-52-60 AND 51-30.