What was found
DURING SCHEDULED C2 INSPECTION NR 26839 ACCOMPLISHMENT FOUND LT RAMP FLOOR PANEL HAT SECTIONS BUCKLED AT EACH END, RS 1 AND 10. REPAIRED PER SRM SMP 583-53-40-30.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C2 INSPECTION NR 26839 ACCOMPLISHMENT FOUND LT RAMP FLOOR PANEL HAT SECTIONS BUCKLED AT EACH END, RS 1 AND 10. REPAIRED PER SRM SMP 583-53-40-30.