What was found
DURING SCHEDULED C2 INSPECTION NR 26994 ACCOMPLISHMENT FOUND FS 228 TO 245, LBL 26 FLOOR SUPPORT INTERCOSTAL CORRODED, WL 146. REPLACED INTERCOSTAL PER SRM SMP 583-51-70.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C2 INSPECTION NR 26994 ACCOMPLISHMENT FOUND FS 228 TO 245, LBL 26 FLOOR SUPPORT INTERCOSTAL CORRODED, WL 146. REPLACED INTERCOSTAL PER SRM SMP 583-51-70.