What was found
DURING SCHEDULED B-1 INSPECTION PER JOB CARD HB0505, FOUND 2 INCH CRACK AT FS 968 RBL 17 IN O/H FORMER. STOP DRILLED, NDT''ED, FABBED REPAIR DOUBLER, AND INSTALLED IAW SRM 53-50-03, 53-50 PAGE 14.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED B-1 INSPECTION PER JOB CARD HB0505, FOUND 2 INCH CRACK AT FS 968 RBL 17 IN O/H FORMER. STOP DRILLED, NDT''ED, FABBED REPAIR DOUBLER, AND INSTALLED IAW SRM 53-50-03, 53-50 PAGE 14.