What was found
DURING SCHEDULED C2 INSPECTION NR 26473 ACCOMPLISHMENT, FOUND FS 245E-345E NR 1 CTR FLOORBOARD CORRODED LBL 15.5 - RBL 15.5. FABRICATED AND REPLACED FLOOR PANEL PER SRM SMP 583-51-60. NR 26564.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C2 INSPECTION NR 26473 ACCOMPLISHMENT, FOUND FS 245E-345E NR 1 CTR FLOORBOARD CORRODED LBL 15.5 - RBL 15.5. FABRICATED AND REPLACED FLOOR PANEL PER SRM SMP 583-51-60. NR 26564.