What was found
DURING SCHEDULED C2 INSPECTION PER JOB CARD HSP53161, FOUND FS 257E FLOORBEAM UPPER CHORD, FWD FLANGE LOWER SURFACE CORRODED AT RBL 40R, WL 146. REPAIRED PER SRM SMP 583-51-140-61.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.