What was found
DURING SCHEDULED C2 INSPECTION PER JOB CARD HSP53161, FOUND LT CHINE CAP CORRODED AT FS 257, 277, 297, 377 AND 397, LBL 50 TO LBL 60, WL 146. REPLACED CHINE PLATE FS 245 TO 517 PER SRM SMP 583-51-40.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C2 INSPECTION PER JOB CARD HSP53161, FOUND LT CHINE CAP CORRODED AT FS 257, 277, 297, 377 AND 397, LBL 50 TO LBL 60, WL 146. REPLACED CHINE PLATE FS 245 TO 517 PER SRM SMP 583-51-40.