What was found
DURING SCHEDULED C2 INSPECTION PER JOB CARD HSP53161, FOUND LT FS 751E RING SEGMENT CORRODED AT WL 140, LBL 61. REPAIRED PER SRM SMP 583-53-40-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C2 INSPECTION PER JOB CARD HSP53161, FOUND LT FS 751E RING SEGMENT CORRODED AT WL 140, LBL 61. REPAIRED PER SRM SMP 583-53-40-11.