What was found
DURING SCHEDULED C3 INSPECTION PER JOB CARD HC3208 FOUND FS 517 LMLG BEAM REINFORCING PLATE CRACKED AT LBL 65, WL 146.REPLACED REINFORCING PLATE PER SRM SMP 583-51-70. NR 0171.