What was found
DURING SCHEDULED C4 INSPECTION PER JOB CARD HSP53161 FOUND FS 796 TO 809 RAMP LH AND RH FLOOR PANELS WITH CRACKED HAT SECTIONS, LBL 60 AND RBL 60, WL 146.REPLACED FLOOR PANELS IAW SRM SMP 583 51-10 PG 4, 51-60 AND 51-70. NR 2183.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C4 INSPECTION PER JOB CARD HSP53161 FOUND FS 796 TO 809 RAMP LH AND RH FLOOR PANELS WITH CRACKED HAT SECTIONS, LBL 60 AND RBL 60, WL 146.REPLACED FLOOR PANELS IAW SRM SMP 583 51-10 PG 4, 51-60 AND 51-70. NR 2183.