What was found
DURING SCHEDULED C5 INSPECTION PER JOB CARD HC5321 FOUND FS 627 FITTING CORRODED AT LONGERON ATTACH, LBL 20, WL 270. REPLACED FITTING IAW SRM SMP 583 51-10 PG 4. NR 2120.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C5 INSPECTION PER JOB CARD HC5321 FOUND FS 627 FITTING CORRODED AT LONGERON ATTACH, LBL 20, WL 270. REPLACED FITTING IAW SRM SMP 583 51-10 PG 4. NR 2120.