What was found
DURING SCHEDULED C-3 CHECK, PER JOB CARD HC5301 FOUND RT MAIN WHEEL WELL OBD FRAME TO DOOR HINGE LONGERON TEE CLIP EXFOLIATION CORROSION AT FS 557. REPAIR ACCOMPLISHED BY REPLACING TEE CLIP IAW LAC MEA 382-53-07-80.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C-3 CHECK, PER JOB CARD HC5301 FOUND RT MAIN WHEEL WELL OBD FRAME TO DOOR HINGE LONGERON TEE CLIP EXFOLIATION CORROSION AT FS 557. REPAIR ACCOMPLISHED BY REPLACING TEE CLIP IAW LAC MEA 382-53-07-80.