What was found
DURING SCHEDULED B-3 CHECK, PER JOB CARD HB5302, FOUND INTERIOR FUSELAGE BHD INBD CAP CRACKED AT FS 814, WL 165, RBL 69. REPAIR ACCOMPLISHED IAW SMP583 FIG 53-50-14.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED B-3 CHECK, PER JOB CARD HB5302, FOUND INTERIOR FUSELAGE BHD INBD CAP CRACKED AT FS 814, WL 165, RBL 69. REPAIR ACCOMPLISHED IAW SMP583 FIG 53-50-14.