What was found
DURING SCHEDULED C-9 CHECK PER JOB CARD HST2708, FOUND RUDDER LOWER AND CENTER AUX BEAMS CRACKED AT FS 1157, VSS0-15, BL0 AND FS 1175.5, VSS0-73, BL0. REPAIRED CENTER BEAM IAW SMP583 FIG 51-140-19 REF FIG 55-50-02 ITEM 11. FABRICATED AND INSTALLED LWR BEAM IAW LMAS DRAWINGS 342012 AND 342240.