What was found
DURING SCHEDULED B-1 CHECK IAW JOB CARD HSP53303, FOUND RT UNDERFLOOR CHINE ANGLE EXFOLIATION CORROSION AT FS517, WL141, LBL61. REPAIRED IAW SRM SMP583 FIG 53-40-27.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED B-1 CHECK IAW JOB CARD HSP53303, FOUND RT UNDERFLOOR CHINE ANGLE EXFOLIATION CORROSION AT FS517, WL141, LBL61. REPAIRED IAW SRM SMP583 FIG 53-40-27.