What was found
DURING SCHEDULED C-10 CHECK PER JOB CARD HC5712 FOUND RT INBOARD UPPER FWD CORNER FITTING NODE THICKNESS EXCEEDING LIMITS. REPLACED CORNER FITTING IAW LOCKHEED SMP583 CHAP 51-60 & 51-70.