What was found
DURING SCHEDULED C-5 CHECK, FOUND RT MLG BEAM OTBD CAP EXFOLIATION CORROSION AND INBD CAP CRACK AT FS517, WL154 TO 165, RBL 63. REPLACED BEAM AND FRAME IAW SMP583 CHAPTER 51-60 & 51-70.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C-5 CHECK, FOUND RT MLG BEAM OTBD CAP EXFOLIATION CORROSION AND INBD CAP CRACK AT FS517, WL154 TO 165, RBL 63. REPLACED BEAM AND FRAME IAW SMP583 CHAPTER 51-60 & 51-70.