What was found
DURING SCHEDULED C-11 CHECK UNDER JOB CARD HC5323, FOUND LT MLG WW BEAM ATTACH WEB FASTENER HOLE 0.250" DIAMETER OVERSIZED 0.188" DIAMETER AT FS 517, WL 168 BL 61.5, REPAIRED IAW SMP583 SRM 51-60 AND 51-70.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C-11 CHECK UNDER JOB CARD HC5323, FOUND LT MLG WW BEAM ATTACH WEB FASTENER HOLE 0.250" DIAMETER OVERSIZED 0.188" DIAMETER AT FS 517, WL 168 BL 61.5, REPAIRED IAW SMP583 SRM 51-60 AND 51-70.