What was found
DURING SCHEDULED C-11 CHECK, WHILE PERFORMING SB 382-57-85 R2 APPENDIX A NDI, FOUND THE LT CENTER WING LOWER SURFACE PANEL UNDER THE LT WING ATTACH ANGLE HAD 1 CRACK EVIDENT; FS 570, CWS 60L, WL 256. REPAIRED IAW LAC MEA 382-57-14-040, NR 2234.