What was found
DURING SCHEDULED C-11 CHECK WHILE PERFORMING SB 382-57-85 R2 APPENDIX A NDI AND SP-141 NDI, FOUND 3 CRACKS EVIDENT ON THE RT FS577-FS617 SIDEWALL AT FS576, FS577, & FS588, RBL61. REPAIR BY REPLACEMENT ACCOMPLISHED IAW SMP583, CHAPTER 51-60 AND 51-70. NR 2267.