What was found
DURING SCHEDULED C-12 CHECK, FOUND THE RAMP DOOR INTERIOR RS6 TO RS8, LBL 3 TO RBL 3 UPPER INTERCOSTAL BEAM WEB HAD 1.5 INCH LONG CRACK. REPLACEMED IAW SRM 51-60 AND 51-70.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C-12 CHECK, FOUND THE RAMP DOOR INTERIOR RS6 TO RS8, LBL 3 TO RBL 3 UPPER INTERCOSTAL BEAM WEB HAD 1.5 INCH LONG CRACK. REPLACEMED IAW SRM 51-60 AND 51-70.