What was found
DURING SCHEDULED C-12 CHECK WHILE PERFORMING OTHER MAINTENANCE, FOUND THE HORIZONTAL STABILZER LOWER SKIN INNER DOUBLER AT FS 1067, LBL 61 - RBL 61, WL 256 HAD EXFOLIATION CORROSION. REPAIRED IAW SRM 51-60 AND 51-70.