What was found
DURING SCHEDULED C-1 CHECK UNDER JOB CARD HC5321, FOUND FLOOR END BHD LOWER CAP CORRODED WITH TEMPORARY REPAIR AT FS817.0E, WL130-140, AND LBL60-RBL60. REPAIR BY REPLACEMENT ACCOMPLISHED IAW SMP583 SRM, CH. 51-60 & 51-70. NR# 2314.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C-1 CHECK UNDER JOB CARD HC5321, FOUND FLOOR END BHD LOWER CAP CORRODED WITH TEMPORARY REPAIR AT FS817.0E, WL130-140, AND LBL60-RBL60. REPAIR BY REPLACEMENT ACCOMPLISHED IAW SMP583 SRM, CH. 51-60 & 51-70. NR# 2314.