What was found
DURING SCHEDULED C-1 CHECK UNDER JOB CARD HC5313, FOUND UNDERFLOOR BEAM LOWER CAP CORRODED AT FS337.0E, WL126-140, AND RBL3-6. REPAIR BY REPLACEMENT ACCOMPLISHED IAW SMP583 SRM, CH. 51-60 & 51-70. NR# 2320.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C-1 CHECK UNDER JOB CARD HC5313, FOUND UNDERFLOOR BEAM LOWER CAP CORRODED AT FS337.0E, WL126-140, AND RBL3-6. REPAIR BY REPLACEMENT ACCOMPLISHED IAW SMP583 SRM, CH. 51-60 & 51-70. NR# 2320.