What was found
DURING SCHEDULED C-1 CHECK UNDER JOB CARD HC5211, FOUND THE RAMP DOOR RT ACTUATOR FITTING EXTERNAL FAIRING CORRODED AND WITH TEMPORARY REPAIRS; RAMP STATION 8, RBL60-75, WL150. REPAIR BY REPLACEMENT ACCOMPLISHED IAW SRM, CH. 51-60 & 51-70. NR# 2502.