As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING SCHEDULED C-1 CHECK UNDER JOB CARD HC5211, FOUND THE RAMP DOOR RAMP STATION 2 BULKHEAD UPPER CAP CORRODED AROUND THE TIE DOWN POINT AT BL 20 & BL 40, AND BL 0. REPAIR BY REPLACEMENT ACCOMPLISHED, IAW LOCKHEED SMP583 SRM, CH 51-60 & 51-70. NR 7259.