What was found
DURING SCHEDULED C-1 CHECK WHILE PERFORMING OTHER MAINTENANCE, FOUND THE FS 797.0E UNDERFLOOR BULKHEAD LOWER CAP WITH MULTIPLE ELONGATED HOLES, AND CORRODED AT LBL 45-LBL 60. REPAIR BY REPLACEMENT ACCOMPLISHED, IAW LOCKHEED SMP583 SRM, CH 51-60 & 51-70. NR 7383.