What was found
DURING SCHEDULED C-1 CHECK UNDER JOB CARD HC5511, FOUND THE RT HORIZONTAL STABILIZER BOX BEAM INTERIOR HSS278R RIB LOWER CAP CORRODED. REPAIRED IAW LAC MEA 382-55-19-301. NR 7543.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C-1 CHECK UNDER JOB CARD HC5511, FOUND THE RT HORIZONTAL STABILIZER BOX BEAM INTERIOR HSS278R RIB LOWER CAP CORRODED. REPAIRED IAW LAC MEA 382-55-19-301. NR 7543.