What was found
DURING P4-LAS SCHEDULED C-3 CHECK UNDER JOB CARD HST5325, FOUND THE CREW COMPARTMENT LT OUTBOARD FLOOR BEAM CORRODED AT FS 200-215, LBL 28, WL 195. REPAIRED IAW LOCKHEED SMP583 SRM, FIGURE 51-140-22 NR 1000309109. PSE 53-30-08, AD 2012-06-09.