What was found
DURING P4-LAS SCHEDULED C-3 CHECK WHILE PERFORMING OTHER MAINTENANCE, FOUND THE CARGO RAMP WITH CORRODED TEE ANGLE AT RAMP STATION 7. REPAIR BY REPLACEMENT ACCOMPLISHED, IAW LOCKHEED SMP583 SRM, CH 51-60 & 51-70 NR 1000315727.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING P4-LAS SCHEDULED C-3 CHECK WHILE PERFORMING OTHER MAINTENANCE, FOUND THE CARGO RAMP WITH CORRODED TEE ANGLE AT RAMP STATION 7. REPAIR BY REPLACEMENT ACCOMPLISHED, IAW LOCKHEED SMP583 SRM, CH 51-60 & 51-70 NR 1000315727.