What was found
DURING P4-LAS SCHEDULED C-3 CHECK WHILE PERFORMING SB 382-57-85 APPENDIX A INSPECTION, FOUND THE LT MLG EXTRUDED RISER PANEL WEB CRACKED THROUGH FASTENER HOLES AT FS 537, FS 557 AND FS 577 WL 255, LBL 61. REPAIR BY REPLACEMENT ACCOMPLISHED, IAW LOCKHEED SMP583 SRM, CH 51-60 & 51-70 NR 1000317473.