What was found
DURING SCHEDULED C-9 CHECK UNDER JOB CARD HC5312, FOUND LH UNDERFLOOR BULKHEAD CAP CORRODED AT FS245.0E, LBL60 TO RBL60, WL146. / REPAIR BY REPLACEMENT ACCOMPLISHED IAW LOCKHEED SMP583 SRM, CH. 51-60 & 51-70. NR# 0228. / PSE# 53-40-11, AD 2012-06-09